Federal Pacific has designed and manufactured a family of laboratory tested and stainless-steel).
Federal Pacific and its Powercon division each independently engineer and manufacture their own distinct metal-enclosed switchgear designs for medium-voltage power distribution and protection. While both product lines serve industrial, commercial, and utility applications using air-insulated load-break interrupter switches across 5kV through 38kV, each brings unique switch technology, current ratings, and engineering capabilities that make them suited for different project requirements.
Both Federal Pacific and Powercon metal-enclosed switchgear are completely factory built, wired, and assembled to customer specifications. These systems share a common set of design principles centered on operator safety, rugged construction, and flexible configuration.
Federal Pacific and Powercon metal-enclosed switchgear is specified for medium-voltage service entrance switching, transformer primary protection, feeder isolation, and source transfer across industrial, commercial, and utility facilities.
Medium-voltage switching and protection for distribution systems.
Reliable medium-voltage distribution for critical power systems.
Primary service entrance and sub-distribution for facilities.
Dependable switching and protection for critical facility infrastructure.
Medium-voltage switching and protection for pumps, compressors, and processing operations.
Reliable switching for treatment facility distribution systems.
Air-insulated load-break interrupter switchgear for primary service entrance, sub-distribution, and feeder switching. Available in manual Type ME and automatic Type MEA configurations with options for vacuum circuit breakers, protective relaying, automatic transfer, and SCADA control.
Heavy-duty metal-enclosed switchgear featuring Torque-Lok load-break switches with fused or unfused configurations and duplex or automatic transfer schemes. Custom-engineered to project specifications for demanding industrial and utility applications.
Maximum Design Voltage
15kV–38kV
BIL (Basic Impulse Level)
95 kV–150 kV
Continuous Current
600A; 1200A available
Fault-Closing
40kA asymmetrical (3 time)
Enclosure Options
NEMA 3R (Standard or Stainless)
Compliance Standard
IEEE C37.74 / C57.12.28
Site-specific configuration support for tailored layouts and integration with existing infrastructure.
On-site guidance for proper equipment placement and system interconnection.
Support for a wide range of circuit configurations, fuse options, and bus arrangements to meet site-specific requirements.
Federal Pacific brings decades of engineering experience and application knowledge to every product it manufactures. Each assembly is completely factory built and operationally tested before shipment, ensuring consistent performance and reliability from the moment it arrives on site.